Abstract

Two effective partial discharge (PD) measurement techniques are used; a galvanic contact measurement technique similar to the IEC 60270 standard measurement and free-space radiometric (FSR) measurement. Several types of PD sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. An AC power supply is applied to the PD source and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power (ERP) of the PD sources using a PD calibration device is determined.

Cite

CITATION STYLE

APA

Jaber, A., Lazaridis, P., Saeed, B., Zhang, Y., Khan, U., Upton, D., … Glover, I. (2017). Assessment of effective radiated power of the partial discharge emulator source. In Lecture Notes of the Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering, LNICST (Vol. 186 LNICST, pp. 108–115). Springer Verlag. https://doi.org/10.1007/978-3-319-53850-1_12