A 1D lumped-parameter/3D CFD approach for pressure drop in the aortic coarctation

0Citations
Citations of this article
4Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aortic Coarctation is a congenital constriction of the aorta that increases blood pressure above the constriction and hinders the flow below it. Based on a 3D surface mesh of a moderate thoracic coarctation, a high quality volume mesh is created using an optimal tetrahedral aspect ratio for whole domain. In order to quantify the severity of this constriction, a coupled 1D lumped-parameter/3D CFD approach is used to calculate the pressure drop through the coarctation. The CFD computation is performed assuming that the arterial wall is rigid and the blood is considered a homogeneous Newtonian fluid with density r = 0.001 gr/mm3 and a dynamic viscosity m = 0.004 gr/mm/sec in laminar flow. The boundary conditions of the 3D model (inlet and outlet conditions) have been calculated using a 1D model. Parallelization procedures will be used in order to increase the performance of the CFD calculations. © 2013 Springer-Verlag.

Cite

CITATION STYLE

APA

Soudah, E., Bordone, M., Davdan, P., & Rossi, R. (2013). A 1D lumped-parameter/3D CFD approach for pressure drop in the aortic coarctation. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (Vol. 7746 LNCS, pp. 26–33). https://doi.org/10.1007/978-3-642-36961-2_4