The dosimetric significance of using 10 MV photons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed

14Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

Abstract

The purpose of the study was to analyse the dosimetric differences when using 10 MV instead of 6 MV for VMAT treatment plans for post-prostatectomy irradiation of the prostate bed. Ten post-prostatectomy prostate bed irradiation cases previously treated using 6 MV with volumetric modulated arc therapy (VMAT) were re-planned using 10 MV with VMAT. Prescription dose was 66.6 Gy with 1.8 Gy per fraction for 37 daily fractions. The same structure set, number of arcs, field sizes, and minimum dose to the Planning Target Volume (PTV) were used for both 6 MV and 10 MV plans. Results were collected for dose to Organs at Risk (OAR) constraints, dose to the target structures, number of monitor units for each arc, Body V5, Conformity Index, and Integral Dose. The mean values were used to compare the 6 MV and 10 MV results. To determine the statistical significance of the results, a paired Student t test and power analysis was performed. Statistically significant lower mean values were observed for the OAR dose constraints for the rectum, bladder-Clinical Target Volume (bladder-CTV), left femoral head, and right femoral head. Also, statistically significant lower mean values were observed for the Body V5, Conformity Index, and Integral Dose. Several dosimetric benefits were observed when using 10 MV instead of 6 MV for VMAT based treatment plans. Benefits include sparing more dose from the OAR while still maintaining the same dose coverage to the PTV. Other benefits include lower Body V 5,Conformity Index, and Integral Dose.

References Powered by Scopus

Volumetric Modulated Arc Therapy for Delivery of Prostate Radiotherapy: Comparison With Intensity-Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy

475Citations
N/AReaders
Get full text

A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy

356Citations
N/AReaders
Get full text

Late rectal toxicity after conformal radiotherapy of prostate cancer (I): Multivariate analysis and dose-response

302Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Energy-dependent OAR sparing and dose conformity for total marrow irradiation of obese patients

12Citations
N/AReaders
Get full text

Secondary bladder and rectal cancer risk estimates following standard fractionated and moderately hypofractionated VMAT for prostate carcinoma

7Citations
N/AReaders
Get full text

Improving plan quality for prostate volumetric-modulated arc therapy

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kleiner, H., & Podgorsak, M. B. (2016). The dosimetric significance of using 10 MV photons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed. Radiology and Oncology, 50(2), 232–237. https://doi.org/10.1515/raon-2016-0012

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

73%

Professor / Associate Prof. 2

18%

Researcher 1

9%

Readers' Discipline

Tooltip

Physics and Astronomy 9

56%

Nursing and Health Professions 4

25%

Medicine and Dentistry 2

13%

Agricultural and Biological Sciences 1

6%

Save time finding and organizing research with Mendeley

Sign up for free