Pile foundation is one type deep foundation that serves to distribute the load of hard soil structure loading which has a high bearing capacity that is located deep enough inside the soil. To determine the bearing capacity of the pile and at the same time control the Calendring results, the Pile Driving Analyzer (PDA) test at 8 pile sections from the 84 point piling section (10% of the number sections), the results were analyzed by CAPWAP SOFTWARE, and the highest bearing capacity of Ru 177 ton and the lowest bearing capacity of 111 tons, is bigger than the plan load which load plans that is 60,9 tons. Finally the PDA safe is bearing bearing capacity of the load planning.
Mendeley helps you to discover research relevant for your work.
CITATION STYLE
Simanjuntak, J. O., & Suita, D. (2017). Analysis of bearing capacity pile foundation with using capwap software for testing pile driving analyzer (PDA) at fasfel development project parlimbungan ketek sikara-kara mandailing natal district (North Sumatera). In Journal of Physics: Conference Series (Vol. 930). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/930/1/012010