Impact of Lock-In Time Constant on Remote Monitoring of Trace Gas in the Atmospheric Column Using Laser Heterodyne Radiometer (LHR)

10Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

The time constant selected for lock-in amplification (LIA) has a crucial impact on observed line shapes in laser heterodyne spectroscopy, in particular in the case of ground-based remote monitoring of trace gas in the atmospheric column using laser heterodyne radiometer (LHR). Con-ventional simulation could not allow validation of LHR spectra measured in a real and complex atmospheric environment exhibiting large temporal and spatial variability (humidity, temperature, pressure, etc) that impact significantly the measured LHR spectra profiles. High-precision spectral measurement is thus crucial to avoid any spectral distortion resulting from the measurement. In this paper, the impact of LIA time constant on spectral line shape is investigated for LHR operating in continuous laser tuning mode, based on analysis of laboratory heterodyne spectra, in terms of signal-to-noise ratio (SNR), line width broadening, absorption depth and line shift. With respect to the given frequency scanning speed in continuous mode and to the halfwidth of the absorption feature to scan, a reasonable scanning time ∆Tscan, the time needed for scanning laser frequency through the halfwidth ∆νHWHM of the absorption line, equal to or longer than 14 times of the LIA time constant τ is concluded in order to efficiently reduce the noise while without significant shift and distortion of the line shape. Experimental validation was carried out using a laser heterodyne absorption spectroscopy approach in the laboratory. Four different combinations of time constants τ and scanning time ∆Tscan were used to record heterodyne spectra of a CH4 absorption line near 1242.00 cm−1 in continuous laser tuning mode. An optimal combination of a scanning time of 137 ms with a time constant of 1 ms was obtained. This optimal combination was used for ground-based measurements of CH4 and N2O in the atmospheric column by LHR. The extracted LHR spectrum is in good agreement with a referenced TCCON (Total Carbon Column Observing Network) FT-IR (Fourier-transform infrared) spectrum.

References Powered by Scopus

The HITRAN2016 molecular spectroscopic database

2644Citations
N/AReaders
Get full text

Luminescence Spectroscopy of Semiconductors

401Citations
N/AReaders
Get full text

Modeling of atmospheric chemistry

183Citations
N/AReaders
Get full text

Cited by Powered by Scopus

High-resolution oxygen-corrected laser heterodyne radiometer (LHR) for stratospheric and tropospheric wind field detection

11Citations
N/AReaders
Get full text

A MEMS modulator-based dual-channel mid-infrared laser heterodyne radiometer for simultaneous remote sensing of atmospheric CH<inf>4</inf>, H<inf>2</inf>O and N<inf>2</inf>O

9Citations
N/AReaders
Get full text

Real-Time Measurement of Atmospheric CO<inf>2</inf>, CH<inf>4</inf> and N<inf>2</inf>O above Rice Fields Based on Laser Heterodyne Radiometers (LHR)

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Shen, F., Wang, G., Xue, Z., Tan, T., Cao, Z., Gao, X., & Chen, W. (2022). Impact of Lock-In Time Constant on Remote Monitoring of Trace Gas in the Atmospheric Column Using Laser Heterodyne Radiometer (LHR). Remote Sensing, 14(12). https://doi.org/10.3390/rs14122923

Readers over time

‘22‘2400.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

100%

Readers' Discipline

Tooltip

Engineering 2

50%

Agricultural and Biological Sciences 1

25%

Environmental Science 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0