19F MRI Imaging Strategies to Reduce Isoflurane Artifacts in In Vivo Images

2Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Isoflurane (ISO) is the most commonly used preclinical inhalation anesthetic. This is a problem in 19F MRI of fluorine contrast agents, as ISO signals cause artifacts that interfere with unambiguous image interpretation and quantification; the two most attractive properties of heteronuclear MRI. We aimed to avoid these artifacts using MRI strategies that can be applied by any pre-clinical researcher. Procedures: Three strategies to avoid ISO chemical shift displacement artifacts (CSDA) in 19F MRI are described and demonstrated with measurements of 19F-containing agents in phantoms and in vivo (n = 3 for all strategies). The success of these strategies is compared to a standard Rapid Acquisition with Relaxation Enhancement (RARE) sequence, with phantom and in vivo validation. ISO artifacts can successfully be avoided by (1) shifting them outside the region of interest using a narrow signal acquisition bandwidth, (2) suppression of ISO by planning a frequency-selective suppression pulse before signal acquisition or by (3) preventing ISO excitation with a 3D sequence with a narrow excitation bandwidth. Results: All three strategies result in complete ISO signal avoidance (p < 0.0001 for all methods). Using a narrow acquisition bandwidth can result in loss of signal to noise ratio and distortion of the image, and a frequency-selective suppression pulse can be incomplete when B1-inhomogeneities are present. Preventing ISO excitation with a narrow excitation pulse in a 3D sequence yields the most robust results (relative SNR 151 ± 28% compared to 2D multislice methods, p = 0.006). Conclusion: We optimized three easily implementable methods to avoid ISO signal artifacts and validated their performance in phantoms and in vivo. We make recommendation on the parameters that pre-clinical studies should report in their method section to make the used approach insightful.

Cite

CITATION STYLE

APA

Staal, A. H. J., Veltien, A., Srinivas, M., & Scheenen, T. W. J. (2022). 19F MRI Imaging Strategies to Reduce Isoflurane Artifacts in In Vivo Images. Molecular Imaging and Biology, 24(1), 71–81. https://doi.org/10.1007/s11307-021-01653-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free