Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis

15Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Background Pulse wave analysis (PWA) is a useful tool for non-invasive assessment of central cardiac measures as subendocardial perfusion (Subendocardial Viability Ratio, SEVR) or contractility (dP/dtmax). The immediate influence of transcatheter aortic valve replacement (TAVR) on these indices has not been investigated yet. Methods We prospectively enrolled 40 patients presenting with severe aortic stenosis receiving TAVR. Central pressure curves were derived from radial and carotid sites using PWA up to 2 days before and 7 days after TAVR. Parameters were compared between peripheral measurement sites. Changes in SEVR, dP/dtmax and in indices of vascular stiffness were assessed. Additionally, association of these variables with clinical outcome was evaluated during a 12-month follow-up. Results Central waveform parameters were comparable between measurement sites. SEVR, but not dP/dtmax, augmentation Index (AIx) or augmentation pressure height (AGPH) correlated significantly with disease severity reflected by peak transvalvular velocity and mean transvalvular pressure gradient over the aortic valve (Vmax, ΔPm) [r = -0.372,p = 0.029 for Vmax and r = -0.371,p = 0.021 for ΔPm]. Vmax decreased from 4.5m/s (IQR:4.1–5.0) to 2.2m/s (IQR:1.9–2.7), (p<0.001). This resulted in a significant increase in SEVR [135.3%(IQR: 115.5–150.8) vs. 140.3%(IQR:123.0–172.5),p = 0.039] and dP/dtmax [666mmHg(IQR:489–891) vs. 927mmHg(IQR:693–1092),p<0.001], and a reduction in AIx [154.8%(IQR:138.3–171.0) vs. 133.5%(IQR:128.3–151.8),p<0.001] and AGPH [34.1%(IQR:26.8–39.0) vs. 25.0%(IQR 21.8–33.7),p = 0.002], confirming the beneficial effects of replacing the stenotic valve. No association of these parameters could be revealed with outcome. Conclusions PWA is suitable for assessing coronary microcirculation and contractility mirrored by SEVR and maxdP/dt in the setting of aortic stenosis. PWA parameters attributed to vascular properties should be interpreted with caution.

Cite

CITATION STYLE

APA

Müller, C., Goliasch, G., Schachinger, S., Kastl, S., Neunteufl, T., Delle-Karth, G., … Pavo, N. (2018). Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis. PLoS ONE, 13(11). https://doi.org/10.1371/journal.pone.0207537

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free