Technical note: Evaluation of a silicone-based custom bolus for radiation therapy of a superficial pelvic tumor

11Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Use of standard-of-care radiation therapy boluses may result in air-gaps between the target surface and bolus, as they may not adequately conform to each patient's unique topography. Such air-gaps can be particularly problematic in cases of superficial pelvic tumor radiation, as the density variation may result in the radiation delivered to the target site being inconsistent with the prescribed dose. To increase bolus fit and thereby dose predictability and homogeneity, we designed and produced a custom silicone bolus for evaluation against the clinical standard. Methods: A custom bolus was created for the pelvic regions of both an anthropomorphic phantom and a pelvic patient with squamous cell carcinoma of the penile shaft. Molds were designed using computed tomography (CT) scans, then 3D-printed and cast with silicone rubber to yield the boluses. Air-gap measurements were performed on custom and standard-of-care Superflab gel sheet boluses by analyzing total volume between the bolus and target surface, as measured from CT scans. Therapeutic doses of radiation were delivered to both boluses. Radiation dose was measured and compared to the expected dose using nine optically stimulated luminescent dosimeters (OSLDs) placed on the phantom. Results: Mean air-gap volume between the bolus and phantom was decreased from 314 ± 141 cm3 with the standard bolus to 4.56 ± 1.59 cm3 using the custom device. In the case of the on-treatment patient, air-gap volume was reduced from 169 cm3 with the standard bolus to 46.1 cm3 with the custom. Dosimetry testing revealed that the mean absolute difference between expected and received doses was 5.69%±4.56% (15.1% maximum) for the standard bolus and 1.91%±1.31% (3.51% maximum) for the custom device. Areas of greater dose difference corresponded to areas of larger air-gap. Conclusions: The custom bolus reduced air-gap and increased predictability of radiation dose delivered compared to the standard bolus. The custom bolus could increase the certainty of prescribed dose-delivery of radiation therapy for superficial tumors.

Author supplied keywords

References Powered by Scopus

Use of 3D printers to create a patient-specific 3D bolus for external beam therapy

138Citations
N/AReaders
Get full text

Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer

123Citations
N/AReaders
Get full text

A customized bolus produced using a 3-dimensional printer for radiotherapy

89Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The development and characterization of an all-purpose bolus for radiotherapy

3Citations
N/AReaders
Get full text

Dosimetric Evaluation of Commercially Available Flat vs. Self-Produced 3D-Conformal Silicone Boluses for the Head and Neck Region

3Citations
N/AReaders
Get full text

Technical note: Commissioning of a low-cost system for directly 3D printed flexible bolus

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Wang, K. M., Rickards, A. J., Bingham, T., Tward, J. D., & Price, R. G. (2022). Technical note: Evaluation of a silicone-based custom bolus for radiation therapy of a superficial pelvic tumor. Journal of Applied Clinical Medical Physics, 23(4). https://doi.org/10.1002/acm2.13538

Readers over time

‘22‘23‘24036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

57%

Lecturer / Post doc 2

29%

Researcher 1

14%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

43%

Physics and Astronomy 3

43%

Engineering 1

14%

Save time finding and organizing research with Mendeley

Sign up for free
0