Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis

0Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare the diagnostic sensitivity of ultra-high-resolution computed tomography (U-HRCT) and HRCT in isolated fenestral otosclerosis (IFO). Methods: A retrospective analysis was conducted on 85 patients (85 ears) diagnosed with IFO between October 2020 and November 2022. U-HRCT (0.1 mm thickness) was performed for 20 ears, HRCT (0.67 mm thickness) for 45 ears, and both for 20 ears. The images were evaluated by general radiologists and neuroradiologists who were blinded to the diagnosis and surgical information. The diagnostic sensitivity of U-HRCT and HRCT for detecting IFO was compared between the two groups. Results: Excellent inter-observer agreement existed between the two neuroradiologists (Cohen’s κ coefficient 0.806, 95% CI 0.692–0.920), with good agreement between the general radiologists (Cohen’s κ coefficient 0.680, 95% CI 0.417–0.943). U-HRCT had a sensitivity of 100% (40/40 ears) for neuroradiologists and 87.5% (35/40 ears) for general radiologists, significantly higher than HRCT (89.2% [58/65 ears] for neuroradiologists; 41.5% [27/65 ears] for general radiologists) (p = 0.042, p′ < 0.000). General radiologists’ sensitivity with HRCT was significantly lower compared to neuroradiologists (p < 0.000), but no significant difference was observed when general radiologists switched to U-HRCT (p = 0.152). Among the 20 ears that underwent both examinations, U-HRCT detected lesions smaller than 1 mm in 5 ears, whereas HRCT’s sensitivity for neuroradiologists was 40% (2/5 ears), significantly lower than for lesions larger than 1 mm (93.3%, 14/15 ears, p = 0.032). Conclusion: U-HRCT exhibits higher sensitivity than HRCT in diagnosing IFO, suggesting its potential as a screening tool for suspected otosclerosis patients. Critical relevance statement: Ultra-high-resolution computed tomography has the potential to become a screening tool in patients with suspected otosclerosis and to bridge the diagnostic accuracy gap between general radiologists and neuroradiologists. Key points: • U-HRCT exhibits higher sensitivity than HRCT in the diagnosis of IFO. • U-HRCT has a significant advantage in the detection of less than 1 mm IFO. • U-HRCT has the potential to be used for screening of patients with suspected otosclerosis. Graphical Abstract: [Figure not available: see fulltext.].

Cite

CITATION STYLE

APA

Xu, N., Ding, H., Tang, R., Li, X., Zhang, Z., Lv, H., … Zhao, P. (2023). Comparative study of the sensitivity of ultra-high-resolution CT and high-resolution CT in the diagnosis of isolated fenestral otosclerosis. Insights into Imaging, 14(1). https://doi.org/10.1186/s13244-023-01562-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free