Impedimetric Sensors for Cyclocreatine Phosphate Determination in Plasma Based on Electropolymerized Poly(o-phenylenediamine) Molecularly Imprinted Polymers

17Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Cyclocreatine and its water-soluble derivative, cyclocreatine phosphate (CCrP), are potent cardioprotective drugs. Based on recent animal studies, CCrP, FDA-awarded Orphan Drug Designation, has a promising role in increasing the success rate of patients undergoing heart transplantation surgery by preserving donor hearts during transportation and improving the recovery of transplanted hearts in recipient patients. In addition, CCrP is under investigation as a promising treatment for creatine transporter deficiency, an X-linked inborn error resulting in a poor quality of life for both the patients and the caregiver. A newly designed molecularly imprinted polymer (MIP) material was fabricated by the anodic electropolymerization of o-phenylenediamine on screen-printed carbon electrodes and was successfully applied as an impedimetric sensor for CCrP determination to dramatically reduce the analysis time during both the clinical trial phases and drug development process. To enhance the overall performance of the proposed sensor, studies were performed to optimize the electropolymerization conditions, incubation time, and pH of the background electrolyte. Scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry were used to characterize the behavior of the developed ultrathin MIP membrane. The CCrP-imprinted polymer has a high recognition affinity for the template molecule because of the formation of 3D complementary cavities within the polymer. The developed MIP impedimetric sensor had good linearity, repeatability, reproducibility, and stability within the linear concentration range of 1 × 10-9 to 1 × 10-7 mol/L, with a low limit of detection down to 2.47 × 10-10 mol/L. To verify the applicability of the proposed sensor, it was used to quantify CCrP in spiked plasma samples.

Cite

CITATION STYLE

APA

Abo-Elmagd, I. F., Mahmoud, A. M., Al-Ghobashy, M. A., Nebsen, M., El Sayed, N. S., Nofal, S., … Elgebaly, S. A. (2021). Impedimetric Sensors for Cyclocreatine Phosphate Determination in Plasma Based on Electropolymerized Poly(o-phenylenediamine) Molecularly Imprinted Polymers. ACS Omega, 6(46), 31282–31291. https://doi.org/10.1021/acsomega.1c05098

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free