An automatic geometrical calibration approach has been developed to calibrate a multiprojector-type light field (LF) display automatically and accurately. The calibration framework based on image mapping is detailed, which transfers the calibration of three-dimensional (3-D) scene into the calibration of two-dimensional image in the diffuser interface. A multiprojectors-type LF display prototype is applied to implement the experimental calibration. Comparison results of the reconstructed 3-D scene before and after calibration show that a better overall performance is obtained through the proposed calibration approach. © The Authors.

Cite

CITATION STYLE

APA

Chen, B., Zhong, Q., Li, H., Liu, X., & Xu, H. (2014). Automatic geometrical calibration for multiprojector-type light field three-dimensional display. Optical Engineering, 53(7), 073107. https://doi.org/10.1117/1.oe.53.7.073107