Modified flow rate algorithm for leak detection in transient state from a liquid pipeline’s operating point change

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This article presents the modified algorithm to improve a detection of a leakage in liquid transmission pipeline. It is focused on the leaks, which occur during changes of pipeline’s operating conditions. The algorithm uses cyclical measurements of flow rate on both ends of the pipeline. In comparison to the well-known and commonly used solution, it is characterized by a new process variable structure and two options of a resulting function. The proposed algorithm was evaluated by carrying out experimental tests on the physical model of a pipeline.

Author supplied keywords

Cite

CITATION STYLE

APA

Ostapkowicz, P., Turkowski, M., & Bratek, A. (2017). Modified flow rate algorithm for leak detection in transient state from a liquid pipeline’s operating point change. In Advances in Intelligent Systems and Computing (Vol. 519, pp. 387–393). Springer Verlag. https://doi.org/10.1007/978-3-319-46490-9_52