An exploratory study with an adaptive continuous intravenous furosemide regimen in neonates treated with extracorporeal membrane oxygenation

12Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: The objective of the present study was to explore a continuous intravenous furosemide regimen that adapts to urine output in neonates treated with extracorporeal membrane oxygenation (ECMO). Methods: Seven neonates admitted to a paediatric surgical intensive care unit for ECMO therapy were treated with a furosemide regimen consisting of a loading bolus (1-2 mg/kg) followed by a continuous infusion at 0.2 mg/kg per hour, which was adjusted according to the target urine production of 6 ml/kg per hour. Therapeutic drug monitoring for furosemide concentrations in blood was performed. Results: The mean ± standard deviation furosemide dose was 0.17 ± 0.06 mg/kg per hour, 0.08 ± 0.04 mg/kg per hour and 0.12 ± 0.07 mg/kg per hour, respectively, on the first day, second day and third day of the study. The median (range of the urine production of the study subjects) urine production over the consecutive study days was 6.8 (0.8-8.4) mg/kg per hour, 6.0 (4.7-8.9) mg/kg per hour and 5.4 (3.4-10.1) ml/kg per hour. The target urine production was reached after a median time of 7 (3-37) hours. The regimen was haemodynamically well tolerated and the median furosemide serum concentration was 3.1 (0.4-12.9) μg/ml, well below the toxic level. Conclusion: The evaluated furosemide infusion appears an effective means to reduce volume overload in neonates treated with ECMO. The data of this preliminary study suggest that the starting dose of furosemide was too high, however, because the urine output was excessive and required frequent adaptations. The results of this study therefore indicate that a novel pharmacokinetic/pharmacodynamic model needs to be developed for neonates treated with ECMO. © 2007 van der Vorst et al., licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

van der Vorst, M. M. J., den Hartigh, J., Wildschut, E., Tibboel, D., & Burggraaf, J. (2007). An exploratory study with an adaptive continuous intravenous furosemide regimen in neonates treated with extracorporeal membrane oxygenation. Critical Care, 11(5). https://doi.org/10.1186/cc6146

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free