Variable size computer-aided detection prompts and mammography film reader decisions

10Citations
Citations of this article
43Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision.Methods: Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests.Results: There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05).Conclusions: For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision. © 2008 Gilbert et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Gilbert, F. J., Astley, S. M., Boggis, C. R. M., McGee, M. A., Griffiths, P. M., Duffy, S. W., … Iyengar, G. (2008). Variable size computer-aided detection prompts and mammography film reader decisions. Breast Cancer Research, 10(4). https://doi.org/10.1186/bcr2137

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free