Impact of Center Left Ventricular Assist Device Volume on Outcomes After Implantation: An INTERMACS Analysis

55Citations
Citations of this article
46Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives This study examined patient outcomes after left ventricular assist device (LVAD) implantation across a range of center surgical volumes. Background In order for a center to qualify for reimbursement, Centers for Medicare and Medicaid Services (CMS) requires it to implant ≥10 LVADs or total artificial hearts over a 3-year period. The impact of center LVAD surgical volumes on patient outcomes has not been thoroughly scrutinized. Methods Center volumes were provided for 7,416 patients undergoing LVAD implantation who were enrolled in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). Center LVAD volume was categorized as either very low (≤10 implants/year, n = 617), low (11 to 30 implants/year, n = 2,561), medium (31 to 50 implants/year, n = 2,458), or high (>50 implants/year, n = 1,750). The main outcome of interest was patient survival based on center volume derived from Kaplan-Meier and multivariate Cox regression. Results Overall survival was associated with center volume (p = 0.003), as follows: 71 ± 1.8% (very low volume), 81 ± 0.8% (low volume), 83 ± 0.8% (medium volume), and 79 ± 1.0% (high volume) at 1 year. Compared with medium volume centers, the 90-day mortality was higher in very low volume (odds ratio [OR]: 1.35; p = 0.04) and high volume (OR: 1.28; p = 0.018) VAD centers. The adjusted hazard ratios (HRs) for mortality were 1.32 (95% confidence interval [CI]: 1.11 to 1.56), 1.07 (95% CI: 0.95 to 1.21), and 1.17 (95% CI: 1.03 to 1.30) for very low, low, and high volume centers, respectively. Center volume did not predict mortality (p = 0.25; n = 3,688) in INTERMACS profile 1 patients (patients who had sustained cardiogenic shock) and profile 2 patients (patients with progressive hemodynamic decline despite inotropes). Conclusions Center volume correlates with post-VAD survival, with worse survival noted at very-low volume centers. These findings suggest that current U.S. VAD center standards warrant reconsideration.

Author supplied keywords

Cite

CITATION STYLE

APA

Cowger, J. A., Stulak, J. M., Shah, P., Dardas, T. F., Pagani, F. D., Dunlay, S. M., … Salerno, C. T. (2017). Impact of Center Left Ventricular Assist Device Volume on Outcomes After Implantation: An INTERMACS Analysis. JACC: Heart Failure, 5(10), 691–699. https://doi.org/10.1016/j.jchf.2017.05.011

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free