In this study, we developed a novel, simple, rapid, and low-cost colloidal gold-based immunochromatography method, with filter paper replacing nitrocellulose membrane as the substrate. To obtain adequately immobilized protein, chitosan was used to functionalize the filter paper. After conditions and parameters were optimized, the novel immunochromatography method was applied for detection of sulfonamide residues in milk. Quantitative detection was accomplished using a smartphone and Photoshop software (Adobe Inc., San Jose, CA), allowing us to screen 13 sulfonamides with a limit of detection ranging from 0.42 to 8.64 μg/L and recovery ranging from 88.2 to 116.9% in milk. The proposed novel method performed similarly to the conventional method that uses a nitrocellulose membrane as the transport medium, and it had lower cost and better usability because of the inexpensive and easily available filter paper.
CITATION STYLE
Zeng, Y., Liang, D., Zheng, P., Zhang, Y., Wang, Z., Mari, G. M., & Jiang, H. (2021). A simple and rapid immunochromatography test based on readily available filter paper modified with chitosan to screen for 13 sulfonamides in milk. Journal of Dairy Science, 104(1), 126–133. https://doi.org/10.3168/jds.2020-18987