Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator

6Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-Tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S-or transvenous (TV)-ICD. Methods and results Consecutive HCM patients implanted with a S-(n = 216) or TV-ICD (n = 211) were enrolled. Propensity-Adjusted cumulative Kaplan Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15 0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20 0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S-and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038 0.79; P = 0.023). The TV-and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27 1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29 1.87; P = 0.521). Conclusion Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-Term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.

Cite

CITATION STYLE

APA

Francia, P., Ziacchi, M., Adduci, C., Ammendola, E., Pieragnoli, P., Filippo, P. D., … Cecchi, F. (2023). Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator. Europace, 25(9). https://doi.org/10.1093/europace/euad270

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free