Critical Study on Corrosion Inhibitors in U-Shaped RCC Beams

7Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

In most structural failures, deterioration of reinforced concrete structure is due to corrosion of reinforcing bars. Ingress of chloride ions and reaction of carbon dioxide with the cement paste due to poor-quality concrete or inadequate cover are the main causes of corrosion. Corrosion can be reduced by using high-quality concrete and providing proper cover to reinforcement. In addition, corrosion inhibitors are used to protect the reinforcement in order to extend the service life of concrete structures. This research work is focused on determining the effectiveness of corrosion inhibitors under cracked and uncracked sections of U-shaped beam. The U-shaped beam concept was used in this study, which helps to develop the crack width within 0.3 mm as per IS: 456 code provision. The two vertical stubs of the U-shaped beam were stressed in order to generate the cracks at the soffit of the beam. Then, the beams are tested for accelerated corrosion along with the half-cell potential meter calculations for the corrosion potential measurement.

Cite

CITATION STYLE

APA

Shanmughan, S., Velusamy, S., Nallasamy, J. L., Selvakumar, K. P., Thirumoorthy, P., Saravanan, M. M., … Kasirajan, R. (2022). Critical Study on Corrosion Inhibitors in U-Shaped RCC Beams. Advances in Materials Science and Engineering, 2022. https://doi.org/10.1155/2022/4762524

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free