Suture of the right internal jugular vein catheter in a mitral valve replacement: A case report

2Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction. Central venous catheterization can be necessary for patients undergoing a cardiac operation. Accidental suturing of the catheter to the heart is a rare complication that is difficult to correct; excessive traction force on the central venous catheter can lead to heart breakage or even death. Case presentation. We describe the case of a 56-year-old Han Chinese woman who was scheduled to undergo mitral valve replacement. The central venous catheter placed into her right internal jugular vein was accidentally sutured to the left atrial suture line during the operation. The stuck catheter was successfully removed without having to perform a cardiopulmonary bypass. Conclusions: Attaching a catheter to the heart by cardiac sutures can occur when the tip of the catheter locates directly above the atrial-caval junction. Care should be taken when closing the cephalad end of a left atrial incision in a mitral valve replacement. Although rare, accidental suturing of the central venous catheter must be kept in mind, and an approach should be chosen to remove the catheter that best avoids additional insult to the heart function. © 2014 Kong et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Kong, H., Chen, S., & Wen, X. (2014). Suture of the right internal jugular vein catheter in a mitral valve replacement: A case report. Journal of Medical Case Reports, 8(1). https://doi.org/10.1186/1752-1947-8-129

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free