Isokinetic characteristics of amateur boxer athletes

8Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

Abstract

Aim: The kinetic chain of the punch of boxers is characterized by the contribution of the shoulder; however, the isokinetic muscle strength of shoulder's rotators muscles has not been well studied so far, especially with regards to performance. Therefore, the aim of the present study was (a) to profile the isokinetic muscle strength of rotators of the glenohumeral joint, bilateral (BL), unilateral (UL) and functional ratios in amateur boxers, and (b) to examine the variation of these muscle strength characteristics by performance level. Methods: Forty male amateur Greek boxers from three division levels (elite, n = 22; second division, n = 11; and third division, n = 7), and 10 non-athletes (control group) were tested, using the isokinetic dynamometer Kin-ComTM in the scapular seated position under standard conditions. We examined (i) peak torque (PT) of internal (IR) and external (ER) rotators during concentric (CON) and eccentric (ECC) contractions at low (60∘/s), medium (120∘/s), and high speed (180∘/s), (ii) BL, (iii) UL, and (iv) functional ratios of dominant (D) and non-dominant (ND) limbs. Results: Boxers were stronger than control group in IR and ER at all speeds, and D outscored ND limb (p < 0.05). Elite boxers were stronger than group B and C (p < 0.05); however, when peak torque was expressed in relative to body mass values, these differences were attenuated. The BL ratios for the men athletes were under 10% at 60 and 180∘/s, the UL ratios were lower at 60 and higher at 180∘/s and significant lower in the dominant limb at all speeds. The functional ratios of IR ECC / ER CON were higher between the control group at all speeds and the ER ECC/IR CON ratios were between 60 and 180∘/s, and the two limbs with higher values at 180∘/s. Conclusion: Boxers had the strongest dominant limb and their BL ratios were normal at all speeds except of 120∘/s ECC. The UL ratios of ECC at 120 and 180∘/s of ND were normal, and at the other speeds abnormal due to high IR. In addition, the functional ratios may be related to the kinetic chain of the punch, which in turn correlates with the contribution of ER of both limbs.

References Powered by Scopus

Preseason strength and flexibility imbalances associated with athletic injuries in female collegiate athletes

554Citations
N/AReaders
Get full text

Kinematic and kinetic comparison of baseball pitching among various levels of development

499Citations
N/AReaders
Get full text

Biomechanics of overhand throwing with implications for injuries

424Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Resistance Training in Face of the Coronavirus Outbreak: Time to Think Outside the Box

23Citations
N/AReaders
Get full text

Lower extremity isokinetic strength characteristics of amateur boxers

6Citations
N/AReaders
Get full text

The reliability of a linear position transducer and commercially available accelerometer to measure punching velocity in junior boxing athletes

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Tasiopoulos, I., Nikolaidis, P. T., Tripolitsioti, A., Stergioulas, A., Rosemann, T., & Knechtle, B. (2018). Isokinetic characteristics of amateur boxer athletes. Frontiers in Physiology, 9(NOV). https://doi.org/10.3389/fphys.2018.01597

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

74%

Researcher 5

26%

Readers' Discipline

Tooltip

Sports and Recreations 17

61%

Nursing and Health Professions 6

21%

Medicine and Dentistry 3

11%

Engineering 2

7%

Save time finding and organizing research with Mendeley

Sign up for free