The purpose of this article is to show how the pressure load profile along a penstock of an hydroplant and the corresponding flow rate is obtained from the pressure signal using a code called ACHYL CF. In particular the paper will present how it is possible to reconstruct the history of the incident after a strong transient state, in the case of two plants with Pelton turbines and one DSPCF device on a branch of the circuit. For plant-1 the DSPCF device observes an overrun of the maximal allowed pressure after the filling of the injector branch and for plant-2, a strong transient leads to the rupture of the penstock.
CITATION STYLE
Kueny, J. L., Combes, G., Lourenço, M., Clary, V., & Ballester, J. L. (2014). Linear pressure profile estimation along a penstock associated with transients due to severe defects. In IOP Conference Series: Earth and Environmental Science (Vol. 22). Institute of Physics Publishing. https://doi.org/10.1088/1755-1315/22/4/042002