Influence of inversion pulse type in assessing lung-oxygen-enhancement by centrically-reordered non-slice-selective inversion-recovery half-Fourier single-shot turbo spin-echo (HASTE) sequence

8Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To demonstrate the influence of inversion pulse type and inversion time for assessment of oxygen-enhancement on centrically-reordered non-slice-selective inversion-recovery (IR) half-Fourier single-shot turbo spin-echo (HASTE) sequence. Matertal and Methods: Phantoms with and without 100% oxygen and three healthy volunteers were studied with two-dimensional (2D) centrically-reordered non-slice selective IR-HASTE sequence with either composite or block inversion-recovery pulse at increasing inversion times from 200 to 1800 msec. Signal-to-noise ratios (SNRs) of phantom, real signal differences, and relative enhancement ratios of lung parenchyma between oxygen-enhanced and non-oxygen-enhanced MR images on composite and block pulse type were statistically compared at each TI. Results: SNRs at TIs of 200 and 400 msec using the composite inversion pulse type were significantly lower than those with the block inversion pulse in the in vivo study (P < 0.05), although no significant differences were observed in the phantom study and in the in vivo study at inversion times greater than or equal to 600 msec. Real signal intensity (SI) differences at 400 and 600 msec of the composite inversion pulse type were significantly higher than those with the block inversion pulse type (P < 0.05). Relative enhancement ratio at 800 msec with the composite inversion pulse were significantly lower than that with the block inversion pulse (P < 0.05). Conclusion: IR pulse type and inversion time have influence on assessment of oxygen-enhancement by centrically-reordered non-slice-selective IR-HASTE sequence. © 2007 Wiley-Liss, Inc.

Cite

CITATION STYLE

APA

Puderbach, M., Ohno, Y., Kawamitsu, H., Koyama, H., Takenaka, D., Nogami, M., … Sugimura, K. (2007). Influence of inversion pulse type in assessing lung-oxygen-enhancement by centrically-reordered non-slice-selective inversion-recovery half-Fourier single-shot turbo spin-echo (HASTE) sequence. Journal of Magnetic Resonance Imaging, 26(4), 1133–1138. https://doi.org/10.1002/jmri.21105

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free