Dental implant location via surface scanner: a pilot study

7Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Implant location is performed after placement to verify that the safety of neighboring anatomic structure and the realizability of prosthetic plan. Routine postoperative location is based on radiological scanning and raises the concerns on radiation exposure and inconveniency in practice. In the present study a location method based on surface scanning was introduced and the accuracy of this method was assessed in vitro. Material and methods: A total of 40 implants were placed in 10 resin mandible models. The models were scanned with intraoral scanner (IS group) and extraoral scanner (ES group). The implant position was located with fusing the images of surface scanning and cone beam computerized tomography (CBCT) after implant placement. Deviations were measured between positions located by surface scanner and postoperative CBCT with the parameters: central deviation at apex (cda), central deviation at hex (cdh), horizontal deviation at apex (hda), horizontal deviation at hex (hdh), vertical deviation at apex (vda), vertical deviation at hex (vdh) and angular deviation (ad). Results: In IS group, the mean value of cda, cdh, hda, hdh, vda, vdh and ad was 0.27 mm, 0.23 mm, 0.12 mm, 0.10 mm, 0.21 mm, 0.19 mm and 0.72°, respectively. In ES group, the mean value of cda, cdh, hda, hdh, vda, vdh and ad was 0.28 mm, 0.25 mm 0.14 mm, 0.11 mm, 0.22 mm, 0.20 mm and 0.68°, respectively. The implant deviations in IS and ES groups were of no significant difference for any of the measurements. Conclusions: Dental implant can be located via surface scanner with acceptable accuracy for postoperative verification. Further clinical investigation is needed to assess the feasibility of the method.

References Powered by Scopus

Current state of the art of computer-guided implant surgery

402Citations
N/AReaders
Get full text

Cone beam computed tomography in implant dentistry: Recommendations for clinical use

313Citations
N/AReaders
Get full text

Accuracy of computer-aided implant placement

259Citations
N/AReaders
Get full text

Cited by Powered by Scopus

In vitro comparison between metal sleeve-free and metal sleeve-incorporated 3d-printed computer-assisted implant surgical guides

22Citations
N/AReaders
Get full text

An overview of three-dimensional imaging devices in dentistry

20Citations
N/AReaders
Get full text

Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study

11Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Zhou, M., Zhou, H., Li, S. yi, & Geng, Y. ming. (2020). Dental implant location via surface scanner: a pilot study. BMC Oral Health, 20(1). https://doi.org/10.1186/s12903-020-01297-y

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

64%

Professor / Associate Prof. 2

14%

Researcher 2

14%

Lecturer / Post doc 1

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 17

94%

Computer Science 1

6%

Save time finding and organizing research with Mendeley

Sign up for free