Placement of dual capsular tension rings for the combined management of traumatic cyclodialysis cleft and zonular dialysis

3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To evaluate the efficacy and safety of placing dual capsular tension rings for the combined management of traumatic cyclodialysis cleft and zonular dialysis. Methods: A modified capsular tension ring was inserted into the ciliary sulcus and a capsular tension ring or modified capsular tension ring was inserted into the capsular bag in 20 eyes in 20 consecutive patients showing signs of ocular hypotony and ectopia lentis. Outcome measures included intraocular pressure, best-corrected visual acuity, and postoperative complications. Results: Dual capsular tension ring placement was performed in 20 patients with a mean age of 48.7 years. The cyclodialysis cleft extended over 2.9 clock hours (range 0.5–6.5). The modified capsular tension ring was successfully inserted into the ciliary sulcus and a capsular tension ring or modified capsular tension ring in the capsular bag in all eyes. At the last follow-up, the cyclodialysis cleft was closed in 16/20 (80.0%) eyes. The intraocular lens was stable in all patients postoperatively. Best-corrected visual acuity, in terms of the logarithm of the minimal angle of resolution, improved from 1.3 ± 0.8 before surgery to 0.4 ± 0.3 after surgery (P < 0.001). Intraocular pressure increased significantly from 10.6 ± 3.2 mmHg before surgery to 13.0 ± 4.8 mmHg after surgery (P = 0.040). Postoperative complications included a painful reversible intraocular pressure spike in four patients (20.0%). Logistic regression revealed no significant factors associated with successful cleft closure and a stable final intraocular pressure of ≥ 10 mmHg. Conclusions: The placement of two capsular tension rings into the ciliary sulcus and the capsular bag is a safe, successful procedure combined for repairing a traumatic cyclodialysis cleft and managing zonular dialysis.

Cite

CITATION STYLE

APA

Chen, J., Lan, L., Tang, Y., Lu, Y., & Jiang, Y. (2020). Placement of dual capsular tension rings for the combined management of traumatic cyclodialysis cleft and zonular dialysis. Eye and Vision, 7(1). https://doi.org/10.1186/s40662-020-00219-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free