Simple quantitation for potential serum disease biomarker peptides, primarily identified by a peptidomics approach in the serum with hypertensive disorders of pregnancy

7Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: We previously reported peptide candidates of disease biomarkers for pregnancy-induced hypertension syndrome using a novel peptidomic analytical method, BLOTCHIP®-MS. The aim of this study was to establish a sandwich enzyme-linked immunosorbent assay system for quantitation of such peptides and to validate their usefulness as disease biomarkers of pregnancy-induced hypertension syndrome including gestational hypertension/pre-eclampsia. Methods: We focused on three peptide fragments, kininogen-1439–456 (PDA039), kininogen-1438–456 (PDA044) and cysteinyl α2-HS-glycoprotein341–367 (PDA071). Using polyclonal antibodies specific for each peptide, suitable conditions for the sandwich enzyme-linked immunosorbent assay system were investigated. The quantitative enzyme-linked immunosorbent assay values were confirmed by quantitative matrix assisted laser desorption/ionization time-of-flight MS analyses. Using the established enzyme-linked immunosorbent assay systems, serum samples from gestational hypertension/pre-eclampsia patients and paired serum samples from healthy pregnant females were analysed. Results: The optimum sandwich enzyme-linked immunosorbent assay conditions for PDA039/044 quantitation were developed. Quantitation of PDA071 by enzyme-linked immunosorbent assay failed, presumably due to issues with polyclonal antibody specificity for the native peptide. Bland–Altman plots showed a satisfactory correlation between the serum PDA039/044 concentration by enzyme-linked immunosorbent assay and that by quantitative MS analysis. Although the PDA044 concentration showed no significant change during pregnancy, including gestational hypertension/pre-eclampsia patients, the serum PDA039 concentration was significantly increased (P < 0.0001) in the patients. Conclusions: The simple quantitation technology for PDA039 by enzyme-linked immunosorbent assay was established for the first time. PDA039 confirmed its clinical utility as a disease biomarker for gestational hypertension/pre-eclampsia by the enzyme-linked immunosorbent assay system using clinical samples. The information provided from the present study would be a new valuable addition in the field of gestational hypertension/pre-eclampsia research.

Cite

CITATION STYLE

APA

Hamamura, K., Nonaka, D., Ishikawa, H., Banzai, M., Yanagida, M., Nojima, M., … Araki, Y. (2016). Simple quantitation for potential serum disease biomarker peptides, primarily identified by a peptidomics approach in the serum with hypertensive disorders of pregnancy. Annals of Clinical Biochemistry, 53(1), 85–96. https://doi.org/10.1177/0004563215583697

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free