Safety of Zilver PTX Drug-Eluting Stent Implantation Following Drug-Coated Balloon Dilation in a Healthy Swine Model

19Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To compare the safety of Zilver PTX drug-eluting stents (DES) following drug-coated balloon (DCB) angioplasty or conventional balloon angioplasty (BA) in a healthy porcine iliofemoral artery model. Methods: DES implantation following DCB (DCB+DES) or BA (BA+DES) was assessed by angiography and histology in the nondiseased iliofemoral arteries of 20 animals, with sacrifice at 1, 3, and 6 months. Safety assessment compared quantitative measures of vessel integrity (eg, preservation of artery geometry, structure, and lumen dimensions; absence of aneurysm; malapposition) and histological parameters (eg, excessive inflammation). The percentage of uncovered struts could not be >30% per section and the endothelial cell loss had to be <50%. The vascular and skeletal muscle changes in the downstream regions were also assessed histologically for evidence of emboli. Results: No significant differences in safety parameters, including inflammation and endothelial cell loss, were observed between the 2 groups at all time points. Percentage of fibrin was significantly higher in DCB+DES at 3 months [20.0% (IQR 11.6, 28.4) vs BA+DES 4.2% (IQR 1.4, 9.6), respectively; p=0.04], with consistent trends between groups at all time points. Medial smooth muscle cell loss peaked at 1 month and was not statistically different between groups at any time point, although the loss was greater in the DCB+DES group. Sections with arterioles exhibiting paclitaxel-associated fibrinoid necrosis in downstream tissues were observed exclusively in the DCB group at 1 month (14.3% of sections) and 3 months (11.5%). Conclusion: This preclinical study suggests that Zilver PTX stent implantation is a safe strategy after DCB angioplasty and might be considered for patients who require stenting after DCB treatment.

Cite

CITATION STYLE

APA

Torii, S., Yahagi, K., Mori, H., Harari, E., Romero, M. E., Kolodgie, F. D., … Finn, A. V. (2018). Safety of Zilver PTX Drug-Eluting Stent Implantation Following Drug-Coated Balloon Dilation in a Healthy Swine Model. Journal of Endovascular Therapy, 25(1), 118–126. https://doi.org/10.1177/1526602817743747

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free