A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study

3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The injection activity of tracer, acquisition time, patient-specific photon attenuation, and large body mass, can influence on image quality. Fixed acquisition time and body mass related injection activity in clinical practice results in a large difference in image quality. Thus, this study proposes a patient-specific acquisition time regimen of 68 Ga-DOTATATE total-body positron emission tomography-computed tomography (PET/CT) to counteract the influence of body mass (BM, kg) on image quality, and acquire an acceptable and constant image of patients with neuroendocrine tumors (NETs). Methods: The development cohort consisting of 19 consecutive patients with full activity (88.7–204.9 MBq, 2.0 ± 0.1 MBq/kg) was to establish the acquisition time regimen. The liver SNR (signal-to-noise ratio, SNRL) was normalized (SNRnorm) by the product of injected activity (MBq) and acquisition time (min). Fitting of SNRnorm against body mass (BM, kg) in linear correlation was performed. Subjective assessment of image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL, and an optimized acquisition regimen based on BM was proposed, and validated its feasibility through the validation cohort of 57 consecutive NET patients with half activity (66.9 ± 11.3 MBq, 1.0 ± 0.1 MBq/kg) and a fixed acquisition time regimen. Results: The linear correlation (R2 = 0.63) between SNRnorm and BM (kg) was SNRnorm = -0.01*BM + 1.50. The threshold SNRL of acceptable image quality was 11.2. The patient-specific variable acquisition time regimen was determined as: t (min) = 125.4/(injective activity)*(-0.01*BM + 1.50)2. Based on that proposed regimen, the average acquisition time for acceptable image quality in the validation cohort was 2.99 ± 0.91 min, ranging from 2.18 to 6.35 min, which was reduced by 36.50% ~ 78.20% compared with the fixed acquisition time of 10 min. Subjective evaluation showed that acceptable image quality could be obtained at 3.00 min in the validation group, with an average subjective score of 3.44 ± 0.53 (kappa = 0.97, 95% CI: 0.96 ~ 0.98). Bland–Altman analysis revealed good agreement between the proposed regimen and the fixed acquisition time cohort. Conclusion: A patient-specific acquisition time regimen was proposed in NET patients in development cohort and validated its feasibility in patients with NETs in validation cohort by 68 Ga-DOTATATE total-body PET/CT imaging. Based on the proposed regimen, the homogenous image quality with optimal acquisition time was available independent of body mass.

Cite

CITATION STYLE

APA

Xiao, J., Yu, H., Sui, X., Liu, G., Cao, Y., Yanzhao, Z., … Shi, H. (2022). A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study. Cancer Imaging, 22(1). https://doi.org/10.1186/s40644-022-00517-8

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free