Effect of load on the bone around bone-anchored amputation prostheses

31Citations
Citations of this article
92Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Osseointegrated transfemoral amputation prostheses have proven successful as an alternative method to the conventional socket-type prostheses. The method improves prosthetic use and thus increases the demands imposed on the bone-implant system. The hypothesis of the present study was that the loads applied to the bone-anchored implant system of amputees would result in locations of high stress and strain transfer to the bone tissue and thus contribute to complications such as unfavourable bone remodeling and/or elevated inflammatory response and/or compromised sealing function at the tissue-abutment interface. In the study, site-specific loading measurements were made on amputees and used as input data in finite element analyses to predict the stress and strain distribution in the bone tissue. Furthermore, a tissue sample retrieved from a patient undergoing implant revision was characterized in order to evaluate the long-term tissue response around the abutment. Within the limit of the evaluated bone properties in the present experiments, it is concluded that the loads applied to the implant system may compromise the sealing function between the bone and the abutment, contributing to resorption of the bone in direct contact with the abutment at the most distal end. This was supported by observations in the retrieved clinical sample of bone resorption and the formation of a soft tissue lining along the abutment interface. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1113–1122, 2017.

References Powered by Scopus

A method for the study of undecalcified bones and teeth with attached soft tissues: The Säge‐Schliff (sawing and grinding) Technique

1631Citations
N/AReaders
Get full text

The elastic and ultimate properties of compact bone tissue

1321Citations
N/AReaders
Get full text

The mechanical behaviour of cancellous bone

847Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Biomechanical Characterisation of Bone-anchored Implant Systems for Amputation Limb Prostheses: A Systematic Review

101Citations
N/AReaders
Get full text

Finite element analysis of the amputated lower limb: A systematic review and recommendations

88Citations
N/AReaders
Get full text

Stiffness memory nanohybrid scaffolds generated by indirect 3D printing for biologically responsive soft implants

28Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Stenlund, P., Trobos, M., Lausmaa, J., Brånemark, R., Thomsen, P., & Palmquist, A. (2017). Effect of load on the bone around bone-anchored amputation prostheses. Journal of Orthopaedic Research, 35(5), 1113–1122. https://doi.org/10.1002/jor.23352

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 36

63%

Researcher 14

25%

Professor / Associate Prof. 6

11%

Lecturer / Post doc 1

2%

Readers' Discipline

Tooltip

Engineering 29

55%

Medicine and Dentistry 14

26%

Nursing and Health Professions 5

9%

Biochemistry, Genetics and Molecular Bi... 5

9%

Save time finding and organizing research with Mendeley

Sign up for free