Operation experience and performance of the first 300MWe CFB boiler developed by DBC in China

16Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In this paper, general layout, design, operational experience and performance of the first 300MWe circulating fluidized bed (CFB) boiler that developed by Dongfang Boiler Group Co., Ltd China, are introduced. The furnace was with large width-depth ratio. The problems occurred during in commissioning were analyzed and the corresponding modifications were presented. Cold-state experiment and operation experience showed that both fluidization quality and circulating flow rate meet the designated value in the frunace. The imbalance of circulating material flow caused by asymmetric layout of three cyclones was very limited. Heating surfaces were safe except wing wall superheater located in upper part of the furnace was overheated at low load. After commissioning, the boiler was correspondingly modified and its performance was excellent.

Cite

CITATION STYLE

APA

Guo, Q., Zheng, X. S., Zhou, Q., Nie, L., Liu, T. S., Hu, X. K., & Lu, J. F. (2009). Operation experience and performance of the first 300MWe CFB boiler developed by DBC in China. In Proceedings of the 20th International Conference on Fluidized Bed Combustion (pp. 237–242). SpringerOpen. https://doi.org/10.1007/978-3-642-02682-9_32

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free