Previous studies on window-windcatchers have shown their effectiveness in capturing the prevailing wind and redirecting it into a building, increasing the actual-to-required ventilation ratio by 9%, above what is required by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). However, the effect of implementing the proposed system on energy performance, energy costs, and thermal comfort has not been studied. Therefore, here, we investigate and test the implementation of the window-windcatcher on a typical residential building, using a validated DesignBuilder model. Compared to the base case (no window-windcatcher), the total annual energy consumption of the entire building ((Formula presented.)), and consequently the cost, is reduced by approximately 23.3% (i.e., from 18,143 kWh/year to 13,911 kWh/year) when using the window-windcatcher. The total annual reduction in thermal discomfort hours is estimated to be 290 h, which corresponds to an average monthly reduction of approximately 24 h.
CITATION STYLE
Nouh Ma’bdeh, S., Fawwaz Alrebei, O., Obeidat, L. M., Al-Radaideh, T., Kaouri, K., & Amhamed, A. I. (2023). Quantifying Energy Reduction and Thermal Comfort for a Residential Building Ventilated with a Window-Windcatcher: A Case Study. Buildings, 13(1). https://doi.org/10.3390/buildings13010086
Mendeley helps you to discover research relevant for your work.