Background: The World Health Organization (WHO) has targeted a reduction in viral hepatitis-related mortality by 65% and incidence by 90% by 2030, necessitating enhanced hepatitis B treatment and prevention programmes in low- and middle-income countries. Hepatitis B e antigen (HBeAg) status is used in the assessment of eligibility for antiviral treatment and for prevention of mother-to-child transmission (PMTCT). Accordingly, the WHO has classified HBeAg rapid diagnostic tests (RDTs) as essential medical devices. Methods: We assessed the performance characteristics of three commercially available HBeAg RDTs (SD Bioline, Alere, South Africa; Creative Diagnostics, USA; and Biopanda Reagents, UK) in two hepatitis B surface antigen-positive cohorts in Blantyre, Malawi: participants of a community study (n = 100) and hospitalised patients with cirrhosis or hepatocellular carcinoma (n = 94). Two investigators, blinded to the reference test result, independently assessed each assay. We used an enzyme-linked immunoassay (Monolisa HBeAg, Bio-Rad, France) as a reference test and quantified HBeAg concentration using dilutions of the WHO HBeAg standard. We related the findings to HBV DNA levels, and evaluated treatment eligibility using the TREAT-B score. Results: Among 194 HBsAg positive patients, median age was 37 years, 42% were femaleand 26% were HIV co-infected. HBeAg prevalence was 47/194 (24%). The three RDTs showed diagnostic sensitivity of 28% (95% CI 16–43), 53% (38–68) and 72% (57–84) and specificity of 96–100% for detection of HBeAg. Overall inter-rater agreement κ statistic was high at 0.9–1.0. Sensitivity for identifying patients at the threshold where antiviral treatment is recommended for PMTCT, with HBV DNA > 200,000 IU/ml (39/194; 20%), was 22, 49 and 54% respectively. Using the RDTs in place of the reference HBeAg assay resulted in 3/43 (9%), 5/43 (12%) and 8/43 (19%) of patients meeting the TREAT-B treatment criteria being misclassified as ineligible for treatment. A relationship between HBeAg concentration and HBeAg detection by RDT was observed. A minimum HBeAg concentration of 2.2–3.1 log10IU/ml was required to yield a reactive RDT. Conclusions: Commercially available HBeAg RDTs lack sufficient sensitivity to accurately classify hepatitis B patients in Malawi. This has implications for hepatitis B public health programs in sub-Saharan Africa. Alternative diagnostic assays are recommended.
CITATION STYLE
Stockdale, A. J., Silungwe, N. M., Shawa, I. T., Kreuels, B., Gordon, M. A., & Geretti, A. M. (2021). Diagnostic performance evaluation of hepatitis B e antigen rapid diagnostic tests in Malawi. BMC Infectious Diseases, 21(1). https://doi.org/10.1186/s12879-021-06134-3
Mendeley helps you to discover research relevant for your work.