Mechanical evaluation of newly developed mouthpiece using polyethylene terephthalate glycol for transoral robotic surgery

7Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Transoral robotic surgery (TORS), performed with the da Vinci surgical system (da Vinci), has been classified as a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a three-dimensional magnified view, ability to see and work around curves or angles, and the availability of two or three robotic arms. At present, however, the da Vinci surgical system does not provide haptic feedback. The potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury, and mandibular fracture. To prevent such intra-operative tooth injuries, we created a mouthpiece made of polyethylene terephthalate glycol (PETG) individually shaped for the patient’s teeth. We compared the safety and efficacy of the PETG mouthpiece with those of a conventional mouthpiece made of ethylene–vinyl acetate (EVA). To determine the difference in tooth injury resulting from the two types of mouthpiece, we constructed an experimental system to measure load and strain. We measured the dynamic load and the strain from the rod to the tooth using the PETG and EVA mouthpiece. The rod was pressed against the tooth model outfitted with two types of mouthpiece and the dynamic load was measured with a load cell and the strain with a strain gage. The maximum dynamic load was 1.29 ± 0.03 kgf for the PETG mouthpiece and 2.24 ± 0.05 kgf for the EVA mouthpiece. The load against the tooth was thus less for the EVA mouthpiece. The strain was −166.84 ± 3.94 and 48.24 ± 7.77 με, respectively, while the load direction was parallel to that of the tooth axis for the PETG mouthpiece and perpendicular to the tooth axis for the EVA mouthpiece. The PETG mouthpiece reduced the tooth load compared with the EVA mouthpiece and the load direction was in parallel to the tooth axis. The PETG mouthpiece thus enhances tooth safety for TORS.

Author supplied keywords

References Powered by Scopus

Transoral robotic surgery (TORS) for base of tongue neoplasms

617Citations
N/AReaders
Get full text

Transoral robotic surgery: Radical tonsillectomy

526Citations
N/AReaders
Get full text

Transoral robotic surgery: A multicenter study to assess feasibility, safety, and surgical margins

412Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Prevalence of haptic feedback in robot-mediated surgery: a systematic review of literature

75Citations
N/AReaders
Get full text

Colour stabilities of three types of orthodontic clear aligners exposed to staining agents

64Citations
N/AReaders
Get full text

Effects of physical aging on thermomechanical behaviors of poly(ethylene terephthalate)-glycol (PETG)

22Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Fujiwara, K., Fukuhara, T., Niimi, K., Sato, T., Kataoka, H., Kitano, H., & Takeuchi, H. (2015). Mechanical evaluation of newly developed mouthpiece using polyethylene terephthalate glycol for transoral robotic surgery. Journal of Robotic Surgery, 9(4), 347–354. https://doi.org/10.1007/s11701-015-0539-7

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

86%

Professor / Associate Prof. 1

14%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

60%

Engineering 2

20%

Chemical Engineering 1

10%

Materials Science 1

10%

Save time finding and organizing research with Mendeley