Comparison of clinical efficacies and safeties of lumen-apposing metal stent and conventional-type metal stent-assisted EUS-guided pancreatic wall-off necrosis drainage: a real-life experience in a tertiary hospital

21Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Endoscopic ultrasound (EUS)-guided drainage of pancreatic wall-off necrosis (WON) with transmural stent is regarded as firstline therapy. We aimed at comparing its efficacy and safety with using fully covered self-expandable metal stent (FCSEMS) and lumen-apposing metal stent (LAMS). Methods: A retrospective review was performed on all consecutive patients with pancreatic WONs who underwent EUS-guided drainage by either FCSEMS or LAMS. Results: From 2011 to 2016, 68 patients (66.2% male, median age, 66.5 years) underwent WON drainage (22/68 (32.4%) using FCSEMSs of size 10 × 60 mm (14/22, Hanarostent; 8/22 Wallflex); 46/68 (67.6%) using LAMSs (38/46 and 8/46 with AXIOS of size 15 × 10 mm and 10 × 10 mm, respectively). These two groups were matched for age (66 vs. 70 years, p 0.514), APACHE II (11.5 vs. 10, p 0.693), causes [72.7 vs. 80.4% by gallstone pancreatitis (p 0.472); 9.1 vs. 10.9% by alcoholism (p 0.818)], WON size (8.5 vs. 9 cm, p 0.322), location (36.4 vs. 26.1% at pancreatic head, p 0.384; 54.5 vs. 65.2% at body/tail, p 0.395), and enterostomy site [63.6 vs. 76.1% via transgastric (p 0.285); 31.8 vs. 19.6% via transduodenal (p 0.267)] and their number of necrosectomy (p 0.978). The technical (100 vs. 93.5%, p 0.219) and clinical (95.5 vs. 93.5%, p 0.749) success and adverse event (22.7 vs. 39.1%, p 0.180; 9.1 vs. 19.6% with bleeding, p 0.271; 4.5 vs. 13% with spontaneous stent migration, p 0.28; 9.1 vs. 6.5% with dislodgement during necrosectomy, p 0.704) of the two groups were comparable without significant different. However, the LAMS group associated with early stent revision compared with FCSEMS group (log rank p 0.048). Conclusions: EUS-guided drainage of WON using FCSEMSs and LAMSs are comparable in efficacy and safety; however, the latter is associated with early stent revision.

Cite

CITATION STYLE

APA

Law, S. T., De La SernaHiguera, C., Simón, P. G., & Pérez-MirandaCastillo, M. (2018). Comparison of clinical efficacies and safeties of lumen-apposing metal stent and conventional-type metal stent-assisted EUS-guided pancreatic wall-off necrosis drainage: a real-life experience in a tertiary hospital. Surgical Endoscopy, 32(5), 2448–2453. https://doi.org/10.1007/s00464-017-5946-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free