Optimal sampling time-point for cyclosporin A concentration monitoring in heart transplant recipients

9Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

The present study was performed to determine an optimal time-point for monitoring the concentration of the immunosuppressive drug cyclosporin A (CsA) in heart transplant patients and its efficacy in the prevention of transplant rejection. A total of 32 transplant recipients were randomly assigned for three treatment approaches. Recipients in groups A (n=11), B (n=13) and C (n=8) received oral administration of CsA at doses of 3.2, 3.5 and 4.4 mg/kg, respectively. The plasma CsA concentrations were examined at 2 h intervals over 12 h. Furthermore, their correlation with the 4 h pharmacokinetic profiles as the area under the plasma CsA concentration vs. time curve (AUC0-4 h) were calculated The efficacy of CsA in inhibiting cardiac allograft rejection was assessed at 2 h after oral CsA intake (C2) and adverse events of the drug were examined in the C2-monitored recipients. The plasma CsA concentration rapidly increased in most recipients with a peak level detected at ~2 h after dosing. Regression analysis revealed that among all time-points assessed, the CsA had the highest correlation with the AUC0-4 h at C2. At C2, increasing CsA doses exhibited a positive association with the measure of AUC0-4 h. The efficacy of increasing CsA target levels at C2 in preventing heart transplant rejection was comparable, as the survival rate was 100% in all of the treatment groups. However, the proportion of recipients with side effects in group A was obviously lower than that in the other two groups. In conclusion, C2 is an ideal time-point for monitoring plasma CsA levels with a utility for individualising the next scheduled dose for each patient to ensure that target levels are maintained and achieve a high efficacy and safety of CsA therapy in heart transplant recipients (clinical trial no. 12002610).

Cite

CITATION STYLE

APA

Jia, Y., Meng, X., Li, Y., Xu, C., Zeng, W., Jiao, Y., & Han, W. (2018). Optimal sampling time-point for cyclosporin A concentration monitoring in heart transplant recipients. Experimental and Therapeutic Medicine, 16(5), 4265–4270. https://doi.org/10.3892/etm.2018.6711

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free