Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia

48Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background and aim: Surgeons currently rely on visual clues to estimate the presence of sufficient vascularity for safe anastomosis. We aimed to assess the accuracy of endoluminal confocal laser endomicroscopy (CLE) and laparoscopic fluorescence-based enhanced reality (FLER), using near-infrared imaging and fluorescence from injected Indocyanine Green, to identify the transition from ischemic to vascular areas in a porcine model of mesenteric ischemia. Methods: Six pigs underwent 1-h sigmoid segmental ischemia. The ischemic area was evaluated by clinical assessment and FLER to determine presumed viable margins. For each sigmoid colon, 5 regions of interest (ROIs) were identified: ischemic (ROI 1), presumed viable margins ROI 2a (distal) and 2b (proximal), and vascular areas 3a (distal) and 3b (proximal). After injection of fluorescein, CLE scanning of the mucosa from the ischemic area toward viable margins was performed. Capillary blood samples were obtained by puncturing the serosa at the ROIs, and capillary lactates were measured with the EDGE® analyzer. Results: Capillary lactates were significantly higher at ROI 1 (4.91 mmol/L) when compared to resection margins (2.8 mmol/L; mean difference: 2.11; p < 0.05) identified by FLER. There was no significant difference in lactates between ROI1 and resection margins identified by clinical evaluation. In 50 % of cases, ROI 2aCLINIC–2bCLINIC were considered to match (<1 cm distance) with ROI 2aFLER–2bFLER. Confocal analysis revealed specific clues to identify the transition from ischemic to viable areas corresponding to those assessed by FLER in 11/12 cases versus 7/12 for those identified by clinical evaluation. Conclusions: In this experimental model, FLER and CLE were more accurate than clinical evaluation to delineate bowel vascularization.

Cite

CITATION STYLE

APA

Diana, M., Dallemagne, B., Chung, H., Nagao, Y., Halvax, P., Agnus, V., … Marescaux, J. (2014). Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia. Surgical Endoscopy, 28(11), 3224–3233. https://doi.org/10.1007/s00464-014-3595-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free