Diagnostic accuracy and inter-observer agreement with the CO-RADS lexicon for CT chest reporting in COVID-19

10Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To measure the diagnostic accuracy and inter-observer agreement with the use of COVID-19 Reporting and Data System (CO-RADS) for detection of COVID-19 on CT chest imaging. Methods: This retrospective study included 164 consecutive patients with clinical suspicion of COVID-19 in whom a CT chest examination was performed at a single institution between April 2020 and July 2020. Of them, 101 patients was RT-PCR positive for COVID-19. Six readers with varying radiological experience (two each of chest radiologists, general radiologists, and radiologists in training) independently assigned a CO-RADS assessment category for each CT chest study. The Fleiss’ K was used to quantify inter-observer agreement. The inter-observer agreement was also assessed based on the duration of onset of symptoms to CT scan. ROC curve analysis was used to determine the diagnostic accuracy of CO-RADS. The area under curve was calculated to determine the reader accuracy for detection of COVID-19 lung involvement with RT-PCR as reference standards. The data sets were plotted in ROC space, and Youden’s J statistic was calculated to determine the threshold cut-off CO-RADS category for COVID-19 positivity. Results: There was overall moderate inter-observer agreement between all readers (Fleiss’ K 0.54 [95% CI 0.54, 0.54]), with substantial agreement among chest radiologists (Fleiss’ K 0.68 [95% CI 0.67, 0.68]), general radiologists (Fleiss’ K 0.61 [95% CI 0.61, 0.61]), and moderate agreement among radiologists-in-training (Fleiss’ K 0.56 [95% CI 0.56, 0.56]). There was overall moderate inter-observer agreement in early disease (stages 1 and 2), with cumulative Fleiss’ K 0.45 [95% CI 0.45, 0.45]). The overall AUC for CO-RADS lexicon scheme to accurately diagnose COVID-19 yielded 0.92 (95% CI 0.91, 0.94) with strong concordance within and between groups, of chests radiologists with AUC of 0.91 (95% CI 0.88, 0.94), general radiologists with AUC 0.96 (95% CI 0.94, 0.98), and radiologists in training with AUC of 0.90 (95% CI 0.87, 0.94). For detecting COVID-19, ROC curve analysis yielded CO-RADS > 3 as the cut-off threshold with sensitivity 90% (95% CI 0.88, 0.93), and specificity of 87% (95% CI 0.83, 0.91). Conclusion: Readers across different levels of experience could accurately identify COVID-19 positive patients using the CO-RADS lexicon with moderate inter-observer agreement and high diagnostic accuracy.

Author supplied keywords

Cite

CITATION STYLE

APA

Nair, A. V., McInnes, M., Jacob, B., Kumar, D., Soman, D. K., Subair, H. S. V., … Al-Heidous, M. (2021). Diagnostic accuracy and inter-observer agreement with the CO-RADS lexicon for CT chest reporting in COVID-19. Emergency Radiology, 28(6), 1045–1054. https://doi.org/10.1007/s10140-021-01967-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free