Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique

27Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

A comparison down to sub-100-fW optical power level was carried out between a low-noise Silicon photodiode and a low optical flux measurement facility based on a double attenuator technique. The comparison was carried out via a silicon single-photon avalanche diode (Si-SPAD), which acted as transfer standard. The measurements were performed at a wavelength of 770 nm using an attenuated laser as a radiation source at optical power levels between approximately 86 fW and approximately 1325 fW, corresponding to approximately 330 000 photons s-1 and approximately 5.2x106 photons s-1, respectively. The mean relative deviation of the detection efficiencies of the Si-SPAD, determined by the Si-photodiode and the low optical flux measurement facility, i.e. between two completely independent traceability routes, was < 0.2%, thus well within the combined standard uncertainty of the two measurements. To our knowledge, this is the first comparison for the detection efficiency of a single photon detector using a direct optical flux measurement by a conventional Si-photodiode at such low power levels.

References Powered by Scopus

Metrology of single-photon sources and detectors: A review

164Citations
N/AReaders
Get full text

High accuracy verification of a correlated-photon-based method for determining photon-counting detection efficiency

144Citations
N/AReaders
Get full text

Absolute measurement of detector quantum efficiency using parametric downconversion

111Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Experimental realization of an absolute single-photon source based on a single nitrogen vacancy center in a nanodiamond

60Citations
N/AReaders
Get full text

A Molecule-Based Single-Photon Source Applied in Quantum Radiometry

32Citations
N/AReaders
Get full text

Experimental demonstration of a predictable single photon source with variable photon flux

18Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Porrovecchio, G., Šmid, M., López, M., Hofer, H., Rodiek, B., & Kück, S. (2016). Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique. Metrologia, 53(4), 1115–1122. https://doi.org/10.1088/0026-1394/53/4/1115

Readers' Seniority

Tooltip

Researcher 6

55%

PhD / Post grad / Masters / Doc 5

45%

Readers' Discipline

Tooltip

Physics and Astronomy 9

69%

Engineering 3

23%

Energy 1

8%

Save time finding and organizing research with Mendeley

Sign up for free