Analysis of the sulfur mustard metabolite 1,1′-sulfonylbis[2-S-(N- acetylcysteinyl)ethane] in urine by negative ion electrospray liquid chromatography-tandem mass spectrometry

33Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A method is described for the analysis of the sulfur mustard metabolite 1,1′-sulfonylbis[2-S-(N-acetylcysteinyl)ethane] in human urine. The analyte was concentrated from urine on a polymeric SPE cartridge and analyzed by liquid chromatography-negative ion electrospray tandem mass spectrometry in the selected reaction monitoring mode. The limit of detection was 0.5-1 ng/mL. The metabolite was detected at concentrations close to the detection limit in samples of urine from two casualties accidentally exposed to sulfur mustard from a First World War munition.

Cite

CITATION STYLE

APA

Read, R. W., & Black, R. M. (2004). Analysis of the sulfur mustard metabolite 1,1′-sulfonylbis[2-S-(N- acetylcysteinyl)ethane] in urine by negative ion electrospray liquid chromatography-tandem mass spectrometry. Journal of Analytical Toxicology, 28(5), 352–356. https://doi.org/10.1093/jat/28.5.352