Counting efficiency of an improved 30-Å condensation nucleus counter

34Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The ultrafine aerosol condensation nucleus counter (UFACNC) developed by Stolzenburg and McMurry (1990) has been improved. This new instrument can detect particles as small as 30 Å in nitrogen at a sample flow rate of 2.5 cm3·s−1. This flow rate is five times that of the earlier design with the same particle counting efficiency. An increased sample flow rate causes an increase in the arrival rate of detected particles. This improves accuracy in estimating the true particle concentration in ultraclean gas systems. In order to demonstrate its high accuracy the new UFACNC was used to measure the concentration of contaminant particles in ultrafiltered nitrogen. This represents the first accurate determination of ultrafine contamination levels in large ultraclean gas systems. The nitrogen was found to contain as few as 1.28 × 10−4 particles/cm3 (3.62/ft3). The higher volumetric flow rate of the new counter reduced the sample standard deviation of the measured count rate. Therefore, in the case of a low particulate count rate, the difference between the measured and instrument noise background count rates could be more accurately resolved. In addition, the new UFACNC was used to demonstrate a new technique for size classifying ultrafine contaminant particles using only a UFACNC, i.e., without a separate size classifier. The results demonstrate that ultrafine particle size distributions can be obtained directly from a stand-alone UFACNC. © 1991 Elsevier Science Publishing Co., Inc.

References Powered by Scopus

An ultrafine aerosol condensation nucleus counter

384Citations
N/AReaders
Get full text

Performance studies of ultrahigh efficiency membrane filters using a 3.5 nm particle detector

4Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The history of condensation nucleus counters

177Citations
N/AReaders
Get full text

The particle detection efficiency curve of the tsi-3010 cpc as a function of the temperature difference between saturator and condenser

116Citations
N/AReaders
Get full text

Ultrafine Aerosol Measurement Using a Condensation Nucleus Counter with Pulse Height Analysis

89Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

McDermott, W. T., Ockovic, R. C., & Stolzenburg, M. R. (1991). Counting efficiency of an improved 30-Å condensation nucleus counter. Aerosol Science and Technology, 14(2), 278–287. https://doi.org/10.1080/02786829108959490

Readers over time

‘11‘21‘22‘23‘24‘2501234

Readers' Seniority

Tooltip

Researcher 2

100%

Readers' Discipline

Tooltip

Engineering 3

75%

Physics and Astronomy 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0