Comparison of the effects of normal and low blood pressure regulation on the optic nerve sheath diameter in robot assisted laparoscopic radical prostatectomy

3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Background: Robot-assisted laparoscopic radical prostatectomy is an advanced and popu-lar surgical technique. However, increased intracranial pressure which is caused by CO2 pneumoperitoneum and Trendelenburg position is the main cerebrovascular effect. Measurement of optic nerve sheath diameter using ocular ultrasound is a noninvasive and reli-able method for the assessment of intracranial pressure. The primary endpoint of this study was to identify whether low blood pressure regulation has any benefit in attenuating an increase of optic nerve sheath diameter during robot-assisted laparoscopic radical prostatec-tomy. Methods: Optic nerve sheath diameter and cerebral oxygen saturation were measured at baseline (supine position), one and two hours after pneumoperitoneum and Trendelenburg position respectively, and after return to supine position in normal (n = 27) and low blood pressure groups (n = 24). Results: Mean optic nerve sheath diameter values measured at one and two hours after pneumoperitoneum and Trendelenburg position were significantly increased compared to the baseline value (P < 0.001 in normal blood pressure group; P = 0.003 in low blood pressure group). However, the mean optic nerve sheath diameter and cerebral oxygen saturation measured at any of the time points as well as degrees of change between the two groups did not show any significant changes. The peak values of optic nerve sheath diameter in normal and low blood pressure groups demonstrated 14.9% and 9.2% increases, respec-tively. Conclusions: Low blood pressure group demonstrated an effect in maintaining an increase of optic nerve sheath diameter less than 10% during CO2 pneumoperitoneum and Trende-lenburg position.

Cite

CITATION STYLE

APA

Park, J. H., Hong, J. H., Kim, J. S., & Kim, H. J. (2021). Comparison of the effects of normal and low blood pressure regulation on the optic nerve sheath diameter in robot assisted laparoscopic radical prostatectomy. Anesthesia and Pain Medicine, 16(3), 248–257. https://doi.org/10.17085/apm.20097

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free