Summary: This observational pilot project was performed as background to eventually create a rapid, automated and accurate assessment of RV systolic function in variable clinical subgroups. We propose new parameters that characterize the global systolic function of the right ventricle with a simple linear measurement. Background: The tricuspid annular plane systolic excursion (TAPSE), which has been used for over a quarter century as a quick estimate of RV systolic function, was revisited using CMR. It shows good correlation with invasive hemodynamics. MRI is the current gold standard to assess the volumes and anatomy of the heart and we can measure TAPSE more precisely with cardiac MRI to accurately detect any current problems TAPSE measurements may suffer from. Methods: We studied 61 patients (32 female; mean age 46 and std. dev. 22yrs) with adequate, high quality, clinical CMR scans using a conventional 1.5T GE scanner were studied. In addition to simulating the echo-TAPSE parameter, additional semi-automated CMR parameters were obtained from manually identified phasic anatomic landmarks that (Figure presented) honored the trajectory of the tricuspid annulus (TA) and right ventricle apex (RVA): 1. TAPSE -Distance traveled by the TA along the direction of the fixed line joining the TA and RVA at end-diastole (simulates echo measure). 2. (Delta) TA-RVA - Difference between lengths of line segments joining the (RVA) and TA at end-diastole and end-systole (recognizes cardiac translation). 3. TA Excursion (TAE) - Euclidean distance traveled by the TA from enddiastole to end-systole (measures just the TA motion). The correlation of these parameters with conventional RVEF was obtained using linear regression analysis, and a p-value less than 0.05 was considered significant. Results: In general, there is a weak correlation between TAPSE and RVEF and a moderate correlation using the newer parameters of (Delta) TA-RVA and TAE. In clinically relevant subgroups such as RV pressure overload (RVPO) and RV volume overload (RVVO), there are statistically significant differences between the traditional and conventional parameters (see Table 1). Conclusions: In this small pilot project, CMR simulation of echo-TAPSE is a very poor marker of RVEF (r = 0.15), but this correlation can be significantly improved using the rapid, semi-automated (Delta) TA-RVA or TAE method. Very importantly, the choice of parameter has diametrically opposed influences on RVVO and RVPO sub-groups ((Delta) TA-RVA in RVVO, r = 0.92; TAE in RVPO, r = 0.70). These findings suggest variable alteration of longitudinal RV myocardial contraction and warrants further investigation.
CITATION STYLE
Naik, S. L., Rodriguez, J. J., Kalra, N., & Sorrell, V. L. (2012). Tricuspid annular plane systolic excursion (TAPSE) revisited using CMR. Journal of Cardiovascular Magnetic Resonance, 14(S1). https://doi.org/10.1186/1532-429x-14-s1-p299
Mendeley helps you to discover research relevant for your work.