Contrast circulation time to assess right ventricular dysfunction in pulmonary embolism: A retrospective pilot study

3Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Objective: To optimize enhancement of pulmonary arteries and facilitate diagnosis of pulmonary embolism (PE), modern computed tomography angiography (CTA) contains a contrast bolus tracking system. We explored the diagnostic accuracy of the time-intensity curves given by this automated system to identify right ventricular dysfunction (RVD) in acute PE. Methods: 114 CTAs with a diagnosis of PE were reviewed. RVD was defined as right-to-left ventricular diameter ratio of 1 or greater. Four parameters on time-intensity curves were identified. Parameters between CTAs with and those without RVD were compared with the Wilcoxon rank-sum test. The ability of the four parameters to discriminate patients with RVD was explored by compiling the area under the operating curves (AUC). Results: The time needed by the contrast media to reach the pulmonary artery [8 seconds (IQR: 7-9) versus 7 seconds (IQR: 6-8), p<0.01], the time needed to reach 40 Hounsfield units (HU) [11 seconds (IQR: 8.5-14) versus 9.5 seconds (IQR: 8-10.5), p<0.01], and the contrast intensity reached after 10 seconds [19 HU (IQR: 4-67) versus 53 HU (IQR: 32-80), p<0.05] were all statistically different between CTA with and CTA without RVD. Those three parameters changed gradually across severity categories of RVD (p<0.05 for trend). Their AUC to identify RVD ranged from 0.63 to 0.66. The slope of contrast intensity over time was not informative: [31 HU/s (IQR: 20-57) in CTA with, compared to 36 HU/s (IQR: 22.5-53) in CTA without RVD, p = 0.60]. Conclusion: Several parameters of the time-intensity curve obtained by the bolus tracking system are associated with RVD assessed on CTA images. Of those, the time needed to reach a predefined threshold seems to be the easiest to obtain in any CTA without additional processing time or contrast injection. However, the performance of those parameters is globally low.

Cite

CITATION STYLE

APA

John, G., Platon, A., Poletti, P. A., Perrier, A., & Bendjelid, K. (2016). Contrast circulation time to assess right ventricular dysfunction in pulmonary embolism: A retrospective pilot study. PLoS ONE, 11(8). https://doi.org/10.1371/journal.pone.0159674

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free