THD Minimization from H-Bridge Cascaded Multilevel Inverter Using Particle Swarm Optimization Technique

  • et al.
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

In this paper, PSO (Particle Swarm Optimization) based technique is proposed to derive optimized switching angles that minimizes the THD (Total Harmonic Distortion) and reduces the effect of selected low order non-triple harmonics from the output of the multilevel inverter. Conventional harmonic elimination techniques have plenty of limitations, and other heuristic techniques also not provide the satisfactory results. In this paper, single phase symmetrical cascaded H-Bridge 11-Level multilevel inverter is considered, and proposed algorithm is utilized to obtain the optimized switching angles that reduced the effect of 5 th , 7 th , 11 th and 13 th non-triplen harmonics from the output voltage of the multilevel inverter. A simulation result indicates that this technique outperforms other methods in terms of minimizing THD and provides high-quality output voltage waveform.

Cite

CITATION STYLE

APA

Memon, M. A., Memon, S. A., & Khan, S. M. (2017). THD Minimization from H-Bridge Cascaded Multilevel Inverter Using Particle Swarm Optimization Technique. Mehran University Research Journal of Engineering and Technology, 36(1), 33–38. https://doi.org/10.22581/muet1982.1701.04