Urinary iodine excretion and serum thyroid function in adults after iodinated contrast administration

36Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Iodinated contrast media (ICM) is a source of excess iodine that may induce thyroid dysfunction. A prospective cohort study was conducted to assess the effects of ICM on urinary iodine clearance and serum thyroid function tests (TFTs) in adults. Methods: In this prospective cohort study of 54 adults undergoing elective computed tomography (CT) scans at an academic medical center, serial urinary iodine concentrations (UIC) and serum TFTs were obtained until UIC normalized following ICM administration. Thyroid volume/nodularity were assessed by ultrasound. Associations between covariates and peak UIC, duration for UIC to peak and normalize, and thyroid dysfunction risk were assessed. Results: The mean±standard deviation (SD) iodine administered was 34.6±6.0g. Baseline median (range) UIC was 105.1 (17.0-866.1)μg/L, and serum thyrotropin (TSH) concentration was 1.26 (0.5-11.2) mIU/L. The mean±SD times to achieve peak UIC (median [range]: 3519 [233-157,500]μg/L] and normalized UIC were 1.1±0.5 and 5.2±4.0 weeks, respectively. Four subjects had elevated baseline TSH, and one had missing baseline TSH values. Of the remaining 49 subjects, 11 (22%) developed an abnormal TSH within one to four weeks (six elevated and five decreased). Administered iodine amount correlated with peak UIC following ICM administration (p<0.001). Increasing age and administered iodine amount predicted peak UIC (p=0.024 and p<0.001, respectively). Age, sex, race/ethnicity, smoking status, family history of thyroid disease, personal or family history of thyroid autoimmunity, thyroid volume, presence of thyroid nodules ≥1cm, iodine dose, baseline UIC, and baseline TFTs were not predictive of durations to achieve peak or normalized UIC. Conclusion: Peak UIC occurred at 1.1 weeks and normalized by 5.2 weeks following ICM administration for outpatient CT scans. Because thyroid dysfunction developed in 22% of individuals following a single ICM dose, monitoring of thyroid function should be considered in at-risk patients.

Cite

CITATION STYLE

APA

Lee, S. Y., Chang, D. L. F., He, X., Pearce, E. N., Braverman, L. E., & Leung, A. M. (2015). Urinary iodine excretion and serum thyroid function in adults after iodinated contrast administration. Thyroid, 25(5), 471–477. https://doi.org/10.1089/thy.2015.0024

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free