OBJECTIVE. The purpose of this article is to evaluate single-source dual-energy CT (DECT) for distinguishing benign and indeterminate adrenal nodules, with attention to the effects of phase of IV contrast enhancement. MATERIALS AND METHODS. A retrospective review revealed 273 contrast-enhanced abdominal DECT examinations from November 2009 through March 2012. Fifty adrenal nodules 0.8 cm or larger were identified in 41 patients (22 women and 19 men; average age, 66 years; age range, 36-88 years). CT postprocessing and measurements were independently performed by two radiologists (readers 1 and 2) for each nodule, as follows: attenuation (in Hounsfield units) on true unenhanced images; contrast-enhanced attenuation (in Hounsfield units) on monochromatic spectral images at 40, 75, and 140 keV; and contrast-enhanced material density (in milligrams per milliliter) on virtual unenhanced images. Nodules were classified as benign (< 10 HU) and indeterminate (≥ 10 HU) according to true unenhanced images. RESULTS. Interreader agreement regarding benign and indeterminate nodules was high (κ = 0.92; 95% CI, 0.8-1.0). At 140 keV, the attenuation of benign nodules was significantly lower (reader 1, 7.0 ± 12.5 HU; reader 2, 7.8 ± 9.2 HU) than that of indeterminate nodules (reader 1, 15.7 ± 20.5 HU [ p = 0.004]; reader 2, 17.5 ± 13.4 HU [ p < 0.0001]). On virtual unenhanced images, benign nodules had significantly lower material density (reader 1, 992.4 ± 9.9 mg/mL; reader 2, 992.7 ± 9.6 mg/mL) than did indeterminate nodules (reader 1, 1001.1 ± 20.5 mg/mL [ p = 0.038]; reader 2, 1007.6 ± 13.4 mg/mL [ p < 0.0001]). CONCLUSION. DECT tools can mathematically subtract iodine or minimize its effects in high-energy reconstructions, approximating unenhanced imaging and potentially reducing the need for additional studies to triage adrenal nodules detected on contrast-enhanced DECT examinations. © American Roentgen Ray Society.

Cite

CITATION STYLE

APA

Glazer, D. I., Maturen, K. E., Kaza, R. K., Francis, I. R., Keshavarzi, N. R., Parker, R. A., & Platt, J. F. (2014). Adrenal incidentaloma triage with single-source (fast-kilovoltage switch) dual-energy CT. American Journal of Roentgenology, 203(2), 329–335. https://doi.org/10.2214/AJR.13.11811

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free