Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

5Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

Background: Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique.Methods: We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis.Results: The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was -2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and -2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study.Conclusions: The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. © 2012 Wegner et al.; licensee BioMed Central Ltd.

References Powered by Scopus

Dislocations after total hip-replacement arthroplasties

2392Citations
N/AReaders
Get full text

Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up

540Citations
N/AReaders
Get full text

The john charnley award: Risk factors for cup malpositioning: Quality improvement through a joint registry at a tertiary hospital

478Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Restoration of the centre of rotation in primary total hip arthroplasty the influence of acetabular floor depth and reaming technique

72Citations
N/AReaders
Get full text

Changes of center of rotation and femoral offset in total hip arthroplasty

41Citations
N/AReaders
Get full text

High Variability of Acetabular Offset in Primary Hip Osteoarthritis Influences Acetabular Reaming—A Computed Tomography–Based Anatomic Study

28Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Wegner, A., Kauther, M. D., Landgraeber, S., & von Knoch, M. (2012). Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study. Journal of Orthopaedic Surgery and Research, 7(1). https://doi.org/10.1186/1749-799X-7-25

Readers over time

‘15‘16‘17‘18‘20‘22‘23‘2402468

Readers' Seniority

Tooltip

Researcher 4

57%

PhD / Post grad / Masters / Doc 3

43%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

60%

Engineering 2

20%

Computer Science 1

10%

Nursing and Health Professions 1

10%

Save time finding and organizing research with Mendeley

Sign up for free
0