Abstract

Background: The Thermo ScientificTMSARS-CoV-2 reverse transcription-polymerase chain reaction (RT-PCR) Detection Workflow, packaged with Applied BiosystemsTM TaqManTM 2019-nCoV Assay Kit v1 targets three different SARS-CoV-2 genomic regions in a single RT-PCR reaction. Objective: To validate the Thermo Scientific SARS-CoV-2 RT-PCR Workflow, for the detection of SARS-CoV-2 virus on stainless-steel surfaces as part of the AOAC Performance Tested MethodSM Emergency Response Validation program. Method: The Applied Biosystems TaqMan 2019-nCoV Assay Kit v1, as part of the Thermo Scientific SARS-CoV-2 RT-PCR Workflow, was evaluated for specificity using in silico analysis of 15 764 SARS-CoV-2 sequences and 65 exclusivity organisms. The Thermo Scientific SARS-CoV-2 RT-PCR Workflow was evaluated in an unpaired study for one environmental surface (stainless steel) and compared to the U.S. Centers for Disease Control and Prevention 2019-Novel Coronavirus RT-PCR Diagnostic Panel, Instructions for Use (Revision 4, Effective 6/12/2020). Results: In silico analysis showed that, of the 15 756 target SARS-CoV-2 genomes analyzed, 99% of the strains/isolates are perfectly matched to at least two of the three assays, and more than 90% have 100% homology to all three assays (ORF1ab, N-gene, S-gene) in the SARS-CoV-2 Kit. None of the 65 non-target strain genomes analyzed showed matching sequences. In the matrix study, the Thermo Scientific SARS-CoV-2 workflow showed comparable detection to the centers of disease control and prevention (CDC) method. Conclusions: The Thermo Scientific SARS-CoV-2 RT-PCR Workflow is an effective procedure for detection of RNA from SARS-CoV-2 virus from stainless steel. Highlights: The workflow provides equivalent performance results with the two tested RNA extraction platforms and the two tested RT-PCR instruments.

Cite

CITATION STYLE

APA

Stephenson, P., Crabtree, D., Evans, K., Salavirta, H., Brzoska, P., Leonte, A. M., … Sohier, D. (2021). Validation of the Thermo ScientificTMSARS-CoV-2 RT-PCR Detection Workflow for the Detection of SARS-CoV-2 from Stainless-Steel Environmental Surface Swabs: AOAC Performance Tested MethodSM012103. Journal of AOAC International, 104(4), 935–947. https://doi.org/10.1093/jaoacint/qsab050

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free