High resolution contrast-enhanced MR angiography in the evaluation of rabbit carotid artery

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This study compared a high resolution contrast-enhanced MR angiography (MRA) sequence to conventional contrast-enhanced MRA sequence for imaging of rabbit carotid artery. Fifteen rabbits underwent an evaluation using both high resolution contrast-enhanced MRA sequence and conventional contrast-enhanced MRA sequence. Siemens 1.5 Tesla Magnetom Vision system was utilized. The parameters of high resolution sequence were: TR/TE= 6.2/2.0 msec, flip angle 25°, matrix 130x512, pixel size 0.96x0.49 mm, partition thickness 1.58 mm, acquisition time 24 sec. The parameters of conventional sequence were: TR/TE=3.8/1.4 msec, flip angle 35°, matrix 110x256, pixel size 1.48x1.02 mm, partition thickness 2mm, acquisition time 10 sec. Maximum intensity projection (MIP) images were created. Both original single slices and MIP images were used for image quality evaluation. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), distinctness of artery edge, and venous contamination were analyzed for both techniques. Higher average CNR and SNR were obtained with high resolution contrast-enhanced MRA, compared to average CNR and SNR with conventional contrast-enhanced MRA. The differences were statistically significant (p<0.01). The artery edge with high resolution method was more distinct than conventional method. Jugular venous contamination was found in five of 15 cases with high resolution contrast-enhanced MRA and in four of 15 cases with conventional contrast-enhanced MRA. High resolution contrast-enhanced MRA has significant potential for high quality noninvasive vascular imaging. The image quality with high resolution contrast-enhanced MRA sequence is better than conventional contrast-enhanced MRA sequence.

References Powered by Scopus

Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis

8300Citations
N/AReaders
Get full text

Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography

260Citations
N/AReaders
Get full text

Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta

236Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Wu, R. H., & Kallmes, D. F. (2005). High resolution contrast-enhanced MR angiography in the evaluation of rabbit carotid artery. Rivista Di Neuroradiologia, 18(5–6), 529–536. https://doi.org/10.1177/197140090501800502