Abstract

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra-and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.

Author supplied keywords

References Powered by Scopus

Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications: Recommendations of the international RDC/TMD consortium network and orofacial pain special interest group

3007Citations
N/AReaders
Get full text

Quantification of human motion: Gait analysis - Benefits and limitations to its application to clinical problems

410Citations
N/AReaders
Get full text

Accuracy assessment and interpretation for optical tracking systems

254Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Effects on Muscular Activity after Surgically Assisted Rapid Palatal Expansion: A Prospective Observational Study

7Citations
N/AReaders
Get full text

Accuracy of a new photometric jaw tracking system in the frontal plane at different recording distances: An in-vitro study

4Citations
N/AReaders
Get full text

Special Issue on Recent Developments in Orthodontics on Craniofacial Orthopedics

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Farronato, M., Tartaglia, G. M., Maspero, C., Gallo, L. M., & Colombo, V. (2021). In vitro and in vivo assessment of a new workflow for the acquisition of mandibular kinematics based on portable tracking system with passive optical reflective markers. Applied Sciences (Switzerland), 11(9). https://doi.org/10.3390/app11093947

Readers over time

‘21‘22‘23‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

50%

Researcher 2

50%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

75%

Sports and Recreations 1

25%

Save time finding and organizing research with Mendeley