Clinical chemistry score versus high-sensitivity cardiac troponin i and T tests alone to identify patients at low or high risk for myocardial infarction or death at presentation to the emergency department

34Citations
Citations of this article
64Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: Testing for high-sensitivity cardiac troponin (hs-cTn) may assist triage and clinical decision-making in patients presenting to the emergency department with symptoms of acute coronary syndrome; however, this could result in the misclassification of risk because of analytical variation or laboratory error. We sought to evaluate a new laboratorybased risk-stratification tool that incorporates tests for hs-cTn, glucose level and estimated glomerular filtration rate to identify patients at risk of myocardial infarction or death when presenting to the emergency department. METHODS: We constructed the clinical chemistry score (CCS) (range 0-5 points) and validated it as a predictor of 30-day myocardial infarction (MI) or death using data from 4 cohort studies involving patients who presented to the emergency department with symptoms suggestive of acute coronary syndrome. We calculated diagnostic parameters for the CCS score separately using high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT). RESULTS: For the combined cohorts (n = 4245), 17.1% of participants had an MI or died within 30 days. A CCS score of 0 points best identified low-risk participants: The hs-cTnI CCS had a sensitivity of 100% (95% confidence interval [CI] 99.5%-100%), with 8.9% (95% CI 8.1%-9.8%) of the population classified as being at low risk of MI or death within 30 days; the hs-cTnT CCS had a sensitivity of 99.9% (95% CI 99.2%-100%), with 10.5% (95% CI 9.6%-11.4%) of the population classified as being at low risk. The CCS had better sensitivity than hscTn alone (hs-cTnI 5 ng/L: 96.6%, 95% CI 95.0%-97.8%; hs-cTnT 6 ng/L: 98.2%, 95% CI 97.0%-99.0%). A CCS score of 5 points best identified patients at high risk (hs-cTnI CCS: Specificity 96.6%, 95% CI 96.0%-97.2%; 11.2% [95% CI 10.3%-12.2%] of the population classified as being at high risk; hs-cTnT CCS: Specificity 94.0%, 95% CI 93.1%-94.7%; 13.1% [95% CI 12.1%-14.1%] of the population classified as being at high risk) compared with using the overall 99th percentiles for the hs-cTn assays (specificity of hs-cTnI 93.2%, 95% CI 92.3-94.0; specificity of hs-cTnT 73.8%, 95% CI 72.3-75.2).

Cite

CITATION STYLE

APA

Kavsak, P. A., Neumann, J. T., Cullen, L., Than, M., Shortt, C., Greenslade, J. H., … Worster, A. (2018). Clinical chemistry score versus high-sensitivity cardiac troponin i and T tests alone to identify patients at low or high risk for myocardial infarction or death at presentation to the emergency department. CMAJ, 190(33), E974–E984. https://doi.org/10.1503/cmaj.180144

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free